DTC B2477 [INSTRUMENT CLUSTER]


B3E090255430W09

DTC B2477
• Configuration error

DETECTION CONDITION

• Configuration error
• Malfunction in the instrument cluster internal circuit

POSSIBLE CAUSE

• Instrument cluster malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION
1
PERFORM INSTRUMENT CLUSTER CONFIGURATION
• Perform instrument cluster configuration.
• Is B2477 displayed?
Yes
Replace the instrument cluster.
No
Go to the next step.
2
VERIFY TROUBLESHOOTING OF DTC B2477 COMPLETED
• Clear the DTC from the memory.
• Is B2477 displayed?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.