SIMULATION FUNCTION [FN4A-EL]


B3E050219090T08
• By using the WDS or equivalent, simulation items for input/output parts preset in the PCM can be optionally selected and operated regardless of PCM control conditions.

Simulation Item Table

X: Available

Simulation item

Applicable component

Unit/Condition

Operation

PCM terminal

IG ON

Idle
LPS
Pressure control solenoid control signal in PCM
%
X
X
SSA/SS1
Shift solenoid A control signal in PCM
%
X
X
SSB/SS2
Shift solenoid B control signal in PCM
%
X
X
SSC/SS3
Shift solenoid C control signal in PCM
%
X
X
SSD/ SS4
Shift solenoid D control signal in PCM
On/Off
X
X
SSE_SS5
Shift solenoid E control signal in PCM
On/Off
X
X